Tag Archives: 1064nm laser

FLH-1064-40-SM-B 1064nm 10W Fiber Laser Operation Video

This is a 1064nm 10W single-mode fiber laser. There are 2 fiber output interfaces. The ‘OUTPUT’ on the left is the actual laser output. The ‘MONITOR’ on the right is the synchronization signal output. The laser power of the synchronization signal output port is very low and is only used by customers in need.

The laser has a cooling fan. The RS232 interface here is used to connect to a computer. The current power can be displayed on the screen. The laser output power can be adjusted by buttons.

1064nm-10w-sm-fiber-laser-benchtop-2

Use the buttons to adjust the laser output power:
The left and right arrow buttons select the digit, and the up and down arrow buttons adjust the value. The middle square button is the confirmation button. Turn the key to the right. The Active indicator lights up, and the laser starts outputting.

The parameter table, Spectral diagram and power stability test of this 1064nm laser.

1064nm-10w-sm-fiber-laser-benchtop-5

1064nm-10w-sm-fiber-laser-benchtop-6

1064nm-10w-sm-fiber-laser-benchtop-7

1064nm Infrared Laser 10W High Power DPSS Laser

It is 1064nm high power laser with heat sink at the bottom of the laser head. It adopts air cooling mode, with 2 cooling fans. The light outlet has a protective cover. The modulation mode can be selected from the original TTL or Analog, and upgraded to be compatible with both.

When the key is turned ON, the laser starts to work. The knob is to adjust the current size, thereby adjusting the laser output power. Preheat for 1 to 5 minutes, and the laser power reaches the maximum value.

1

The connector connecting the laser head to the power supply has a protective cover. When installing the laser, it needs to be unscrewed first.

5

6

 

1064nm 15W Semiconductor Laser with Radiator Extend the Working Time

This is a laser system that adjusts the power by adjusting the current. To adjust the current, turn the ‘Adjustor’ knob clockwise, when the current exceeds the min working current, the Laser indicator turns green, and there is laser output. ‘Adjustor’ rotates clockwise to the end, which is the max working current and the max output power of the laser. In addition, the red STOP button is used for emergency stop, and it is not needed under normal circumstances. Let’s check it now.

This is a 1064nm 15W high power infrared laser. An aluminum heat sink is installed under the laser module, which can effectively extend the continuous working time. The radiator is equipped with two cooling fans. There is a small power interface on the side of the data cable close to the laser head for the cooling fan. In addition, the Lock crystal head cannot be pulled out. External signal Mod Input, no need to connect in CW mode. The IR laser supports 3 working modes: CW/TTL/Analog. The above video demonstrates CW working mode.

1064nm-15w-laser-system-1

1064nm-15w-laser-system-3

1064nm is invisible to the human eye. We use an infrared photosensitive film to view the light spot.

Safety reminder:
Wear laser safety glasses when operating high-power lasers.
Laser irradiation of human eyes and skin is prohibited.